Aliases Required By Specific Processes
The following table lists the aliases that have to be set in order to run specific processes for processing airborne gamma-ray data. Note how the "output fields" become the "input fields" for subsequent processes – so the processes must be run in a specific order! See Tutorial 1 – Processing Airborne Data for the sequence of processing steps.
Alias-By-Process Table
Process |
Aliases Required (input fields) |
Fields Created (output fields) |
Comments |
NASVD |
Spectra Down Nasvd Group/Cluster |
Nasvd Amplitudes Nasvd Vectors |
"Nasvd Vectors" is a binary file located outside the database in the working directory |
Energy Calibration (downward-looking detector spectra) |
Spectra Down Encal Group |
"base" "gain" |
The "base" and "gain" database fields names are pre-set by GammaSpec |
Energy Calibration (upward-looking detector spectra) |
Spectra Up Encal Group |
"base_up" "gain_up" |
The "base_up" and "gain_up" database fields names are pre-set by GammaSpec |
Window (raw downward-looking detector spectra) |
Spectra Down Livetime "base" "gain" |
Total Count Raw Potassium Raw Uranium Raw Thorium Raw |
|
Window (Nasvd'd downward-looking detector spectra) |
Nasvd Amplitudes Nasvd Vectors Livetime "base" "gain" |
Total Count Nasvd Potassium Nasvd Uranium Nasvd Thorium Nasvd |
|
Window (raw upward-looking detector spectra) |
Spectra Up Livetime "base_up" "gain_up" |
Uranium Upward |
|
Corrections (for raw window data) |
Potassium Raw Uranium Raw Thorium Raw Uranium Upward* Cosmic Altimeter Temperature Pressure |
Potassium Corrected Uranium Corrected Thorium Corrected |
For the Window Data Source setting set to "Raw spec". * For upward-looking detector background estimation only |
Corrections (for Nasvd'd window data) |
Potassium Nasvd Uranium Nasvd Thorium Nasvd Uranium Upward* Cosmic Altimeter Temperature Pressure |
Potassium Nas Corr Uranium Nas Corr Thorium Nas Corr |
For the Window Data Source setting set to "NASVD spec". * For upward-looking detector background estimation only |